In most cases, the refrigerant leaving the evaporator must be ____...
In a water-cooled condenser, the leaving water temperature is normally...
The automatic expansion valve maintains a constant ____.
Refrigerant entering the evaporator is approximately ____% liquid.
The TX valve maintains a constant ____.
The low form of plant life that grows in condenser water is ____.
As a rule of thumb, the temperature of the evaporator should be about...
An evaporative condenser uses ____ and ____ as the transfer medium for...
If an air-cooled condenser's fan motor stops running, the heat...
In order for a flooded condenser type head pressure control system to...
The correct term for a coil using a low side float is ____.
One large problem designer's face when designing air-cooled...
As the evaporator load increases, an automatic expansion valve will...
The refrigerant in the evaporator must be colder than the air passing...
Low suction pressures, iced coils, short-cycling, and inefficient...
The two primary functions of an evaporator are to remove ____ and ____...
When the velocity of the air moving over an evaporator is slow, the...
Evaporative condensers operate more efficiently in climates where the...
If a low temperature evaporator is forming excess ice, which of the...
A typical evaporator operating temperature in an air-conditioning...
A typical superheat for an evaporator operating under normal...
The capacity of an evaporator is affected by ____.
The condenser in a refrigeration system ____.
If a spring pressure of a water regulating valve is increased, the...
When the quantity of refrigerant flow to an evaporator is reduced, the...
Condensing temperatures in an air-cooled condensing unit can be...
A defrost system that pipes the compressor discharge vapor directly to...
The two pressures that push to close a thermostatic expansion valve...
A stamped plate evaporator usually does not use a fan to move air...
Hard starting may also occur in a low ambient conditions causing low...
If an evaporator has a pressure drop of 10 psig and the low side...
A large capacity evaporator would probably have ____.
If an R-12 refrigeration system has its air-cooled condensing unit on...
The refrigerant in a condenser in a refrigeration system ____.
If an R-12 refrigeration system is operating with a 25.4 psig suction...
Mineral deposits in the water portion of a water-cooled condenser act...
The desired water flow through a condenser connecting to a...
If the application requires a coil design to operate below 32°F,...
The shell and tube condenser is cleaned ____.
A forced draft high temperature evaporator would ____.
If the waterflow is reduced, the temperature difference across a...
During the defrost cycle of a forced draft low temperature evaporator,...
Control of the head pressure in an air-cooled condenser is done by...
If a high temperature evaporator is forming ice, which of the...
Fewer fins per inch on an evaporator allow more ice to build between...
A refrigeration system designed for the storage of flowers or candy...
A normally operating water-cooled condenser is operating with a 10°
...
An air-cooled condenser that is operating in a climate that has four...
The water circuit in shell and coil and coil-type tube-in-a-tube...
The device used to feed refrigerant to multiple circuits in an...
A direct expansion-type evaporator is also called a ____.
A forced draft medium temperature evaporator would ____.
Excess evaporator superheat ____.
When a system with a water-cooled condenser cycles off, the water...
Which of the following can be used to maintain the head pressure of a...
If a low temperature evaporator is forming ice, which of the following...
In a water-cooled condenser with dirty condenser tubes, the...
An evaporator made up of two or more pieces of sheet metal dimpled to...
Which of the following would allow a system to operate more...
Which of the following condensers is the most efficient?
SEER is calculated based on the total amount of ____ the system will...
Every central split cooling system manufactured in the USA today must...
High head pressures from low ambients can cause insufficient...
A water regulating valve helps maintain in a system's head pressure by...
A normally operating water-cooled condenser is operating with a 10°
...
In a water-cooled condenser, a regulating valve is used to control...
The heat required for off-cycle defrost is obtained from ____.
What can be used to maintain the head pressure of a system with a...