1. A vertical opening through a building for elevators, dumbwaiters, mechanical equipment, or similar purposes.

Submit
Please wait...
About This Quiz
Building Laws 06 - Quiz

(PD 1096 National Building Code)
Prepared by:
Arch. /EnP. RSGabitan

2.

What first name or nickname would you like us to use?

You may optionally provide this to label your report, leaderboard, or certificate.

2. As per PD 1096, floors above the first storey in all types of occupancies having an occupant load of more than ten (10) shall not have less than how many exits?

Submit

3. All dry standpipes shall be equipped with this fire department connection which is located on a street front of the building and not less than 300mm nor more than 1.20 mtrs above the grade and shall be equipped with clapper checks and substantial plugs.

Submit

4. A wall separating two or more buildings, and used in common by the said buildings

Submit

5. As per PD 1096, rooms intended for any use, not provided with artificial ventilation system, shall be provided with a window or windows with a total free area of openings equal to at least how many percent of the total floor area of the room?

Submit

6. A projecting window similar to a bay window, but carried on brackets or corbels.

Submit

7. A lot fronting on but one street or public alley and the remaining sides bounded by lot lines.

Submit

8. The line formed by the intersection of the outer surface of the enclosing wall of the building and the surface of the ground.

Submit

9. Every building with _______storeys in height shall be equipped with one or more dry standpipes.

Submit

10. A movable shelter supported entirely from the exterior wall of a building and of a type which can be retracted, folded, or collapsed against the face of a supporting building

Submit

11. Which is exempted from paying building permit fees?

Submit

12. A yard or court providing egress to a public way for one or more required units.

Submit

13. Multi-family living units regardless of number of stories with an average living unit floor area above 50 sqm to 100 sqm shall have 1 parking slot per how many living units.

Submit

14. As per PD 1096, what is the minimum width of a planting strip on the outer side of a sidewalk of 2 meters in width or more, separating the curb from the sidewalk pavement?

Submit

15. The vacant space left between the building and the property lines.

Submit

16. As per PD 1096, what is the minimum horizontal distance between the curb line and the outermost face of any part of the arcade that is cantilevered from the building line over the sidewalk?

Submit

17. As per PD 1096, A.T.O. need not be consulted if buildings/structures is not more than how many meters in height beyond the 315 mtrs. or 500 mtrs. distance from strip edge?

Submit

18. As per PD 1096, what is the range of slope of the entry ramp of the driveway connecting the roadway surface to the sidewalk surface?

Submit

19. As per PD 1096, repair garages and shops shall fall under what occupancy classification?

Explanation

Group D - Government and Health Services (Institutional).
Group E - Business and Mercantile (Commercial).
Group F - Industrial (Non-Pollutive/Non-hazardous Industries and Non-Pollutive/Hazardous Industries)..

Submit

20. Standard automatic fire extinguishing systems shall be installed in every storey, basement or cellar with an area of ____square meters or more which is used for habitation, recreation, dining, study or work, and which has an occupant load of more than 20.

Submit

21. Standpipes shall be located within the following areas. i.   Enclosed stairway landings or near such stairways ii.  Outside exit stairway iii. 300mm of an opening in a stairway enclosure                                                              iv. Immediately inside of an exterior wall

Submit

22. The total aggregate area of plastics used in skylights, monitors, and sawtooth glazing shall not exceed how many percent of the floor area of the room or occupancy sheltered.

Submit

23. The number of wet standpipes when required shall be so determined that all portions of the building are within  6.0 meters of a nozzle attached to a hose ____ meters in length

Submit

24. As per PD 1096, the parking requirements for mixed occupancies shall be the sum of ____% of the dominant use and _____% of the each of the non-dominant use.

Submit

25. As per PD 1096, what is the width of the access road directly connecting multiple living units of 16 to 25 units on same lot to a public street or alley?

Submit

26. As per PD 1096, what is the total open space within lots (TOSL) for basic R-2 buildings/structures on basic R-2 corner lot using minimum sizes?

Submit
×
Saved
Thank you for your feedback!
View My Results
Cancel
  • All
    All (26)
  • Unanswered
    Unanswered ()
  • Answered
    Answered ()
A vertical opening through a building for ...
As per PD 1096, floors above the first storey in all types of...
All dry standpipes shall be equipped with this ...
A wall separating two or more buildings, and used in common ...
As per PD 1096, rooms intended for any use, not provided with...
A projecting window similar to a bay window, but ...
A lot fronting on but one street or public alley ...
The line formed by the intersection of the outer ...
Every building with _______storeys in height ...
A movable shelter supported entirely from the exterior wall ...
Which is exempted from paying building permit fees?
A yard or court providing egress to a public way for one or ...
Multi-family living units regardless of number ...
As per PD 1096, what is the minimum width of a planting strip on the...
The vacant space left between the building and the property lines.
As per PD 1096, what is the minimum horizontal distance between the...
As per PD 1096, A.T.O. need not be consulted if buildings/structures...
As per PD 1096, what is the range of slope of the entry ramp of the...
As per PD 1096, repair garages and shops shall fall under what...
Standard automatic fire extinguishing systems ...
Standpipes shall be located within the following areas. ...
The total aggregate area of plastics used in ...
The number of wet standpipes when required shall ...
As per PD 1096, the parking requirements for mixed occupancies shall...
As per PD 1096, what is the width of the access road directly...
As per PD 1096, what is the total open space within lots (TOSL) for...