The editorial team at ProProfs Quizzes consists of a select group of subject experts, trivia writers, and quiz masters who have authored over 10,000 quizzes taken by more than 100 million users. This team includes our in-house seasoned quiz moderators and subject matter experts. Our editorial experts, spread across the world, are rigorously trained using our comprehensive guidelines to ensure that you receive the highest quality quizzes.
Learn about Our Editorial Process
| By Kubo
K
Kubo
Community Contributor
Quizzes Created: 16 | Total Attempts: 137,965
Questions: 100 | Attempts: 527

SettingsSettingsSettings
Quiz On Fire Alarm Systems And Elevator Control! Trivia Questions Quiz - Quiz

Welcome to this Quiz On Fire Alarm Systems And Elevator Control! Systems exist to assist in possible outcomes from the configurations such as Fire Alarm Systems and Elevator Control, which if well mastered and understood they can be life-savers. A better understanding of them is vital in the firefighting to reduce the probability of injury or loss of life and limits damage. Take the test and see if you understand the systems.


Questions and Answers
  • 1. 

    What is installed in the ducts and mechanical passageways to prevent the fire from spreading?

    • A.

      Fire stopper

    • B.

      Fire dampers

    • C.

      Fire extinguisher

    • D.

      Hose reel

    Correct Answer
    B. Fire dampers
    Explanation
    Fire dampers are installed in ducts and mechanical passageways to prevent the spread of fire. These dampers are designed to automatically close when they detect heat or smoke, effectively blocking the passage of fire and smoke. This helps to contain the fire and prevent it from spreading to other areas of a building. Fire dampers are an important safety feature in buildings, as they help to protect occupants and minimize property damage in the event of a fire.

    Rate this question:

  • 2. 

    Why escalators have a built-in fire alarm system?

    • A.

      Device and body of escalator is not 100% fire proof

    • B.

      Device of the escalator have wiring and sensitive parts that is more sensitive to fire and egnition

    • C.

      It's the hole for each floors

    • D.

      Best location for alarm system as it is located in common areas

    Correct Answer
    C. It's the hole for each floors
    Explanation
    The correct answer is that escalators have a built-in fire alarm system because it is the best location for the alarm system as it is located in common areas.

    Rate this question:

  • 3. 

    When water comes out as soon s the fire sprinkler system is activated, this system is called?

    • A.

      Wet pipe

    • B.

      Dry pipe

    • C.

      Pre-action

    • D.

      Deluge fire system

    Correct Answer
    A. Wet pipe
    Explanation
    When water comes out as soon as the fire sprinkler system is activated, it indicates that the system is already filled with water. This type of system, known as a wet pipe system, is the most common and simplest type of sprinkler system. It is designed for areas where the temperature is above freezing, as the water in the pipes is constantly pressurized and ready to be discharged immediately upon activation. This ensures a rapid response to a fire and helps to suppress it effectively. The other options, such as dry pipe, pre-action, and deluge fire systems, have different mechanisms and are used in specific situations.

    Rate this question:

  • 4. 

    A fire proof door with metal covering?

    • A.

      Kalamein

    • B.

      Panic bar door

    • C.

      Metal door

    • D.

      Fire doors

    Correct Answer
    A. Kalamein
    Explanation
    Kalamein is the correct answer because it refers to a type of fireproof door with a metal covering. This type of door is designed to withstand high temperatures and prevent the spread of fire. It is commonly used in commercial buildings and other areas where fire safety is a priority. The metal covering provides additional protection and durability, making it an effective choice for fire doors.

    Rate this question:

  • 5. 

    Smoke prevention is : more important than fire prevention as important as fire prevention x less important than fire prevention, because fire is more critical than smoke it doesn't matter, it's just smoke.

    • A.

      More important than fire prevention

    • B.

      as important as fire prevention

    • C.

      less important than fire prevention, because fire is more critical than smoke less important than fire prevention, because fire is more critical than smoke

    • D.

      It doesn't matter, it's just a smoke

    Correct Answer
    B. as important as fire prevention
    Explanation
    The correct answer is "as important as fire prevention" because smoke prevention is just as crucial as fire prevention. Smoke is often an early indicator of a fire and can be just as dangerous, if not more, due to the inhalation of toxic fumes. Therefore, both fire prevention and smoke prevention should be given equal importance in order to ensure the safety of individuals and minimize potential damage.

    Rate this question:

  • 6. 

    Why Cable wires and grounding wires are shielded?

    • A.

      Causes magnet

    • B.

      Protects against dust and water

    • C.

      Fire proofing

    • D.

      All of the above

    Correct Answer
    C. Fire proofing
    Explanation
    Cable wires and grounding wires are shielded for fireproofing purposes. Shielding helps prevent the spread of fire by containing any potential sparks or flames within the wires, reducing the risk of fire hazards. It acts as a protective barrier, minimizing the chances of fire accidents caused by electrical faults or short circuits. Shielding provides an additional layer of safety, ensuring that the wires can withstand high temperatures and prevent fires from spreading in case of emergencies.

    Rate this question:

  • 7. 

    Safest material for exits?

    • A.

      Reinforced concrete

    • B.

      Steel

    • C.

      Mortar

    • D.

      All of the above

    Correct Answer
    B. Steel
    Explanation
    Steel is the safest material for exits because it has high strength and durability, making it resistant to fire, impact, and other hazards. It can withstand extreme temperatures and provide structural stability during emergencies, ensuring the safety of people exiting a building. Reinforced concrete and mortar may also offer some level of safety, but steel is specifically designed and widely recognized for its superior performance in exit applications. Therefore, steel is considered the safest material for exits.

    Rate this question:

  • 8. 

    Material best used for stairs in a fire restrictive zone?

    • A.

      Steel

    • B.

      Reinforced concrete

    • C.

      Glass and steel

    • D.

      Steel and metal cladding

    Correct Answer
    B. Reinforced concrete
    Explanation
    Reinforced concrete is the best material for stairs in a fire restrictive zone because it has excellent fire resistance properties. Concrete is a non-combustible material and does not contribute to the spread of fire. Additionally, the presence of steel reinforcement provides added strength and durability to the structure. This combination of concrete and steel makes reinforced concrete a reliable choice for stairs in areas where fire safety is a priority.

    Rate this question:

  • 9. 

    Which material is the least fire resistant?

    • A.

      Gypsum

    • B.

      Wood

    • C.

      Chb

    • D.

      Steel

    Correct Answer
    B. Wood
    Explanation
    Wood is the least fire resistant material among the options given. Wood is a combustible material that easily catches fire and burns rapidly. It has a low ignition point and releases flammable gases when heated, which further fuels the fire. In comparison, gypsum, CHB (concrete hollow blocks), and steel have higher fire resistance properties. Gypsum is a non-combustible material that acts as a fire barrier, while CHB and steel are less prone to burning and can withstand high temperatures for a longer time before succumbing to fire.

    Rate this question:

  • 10. 

    Why should rags not be left beside the can of paints at job sites especially during night time when it is most likely to be unattended?

    • A.

      It will absorb air moisture and dirt to affect the paint

    • B.

      It can be mistaken as a trash can and easily be stolen

    • C.

      It might ignite fire

    • D.

      Some workers work at night time, they might use the rugs as paint brush to paint walls

    Correct Answer
    C. It might ignite fire
    Explanation
    Leaving rags beside a can of paints at job sites, especially during nighttime when it is unattended, can be dangerous because they might ignite a fire. Rags can become flammable when they come into contact with certain chemicals or substances found in paints. If the rags are left in a pile or in a confined space, they can generate heat and potentially catch fire. This can lead to a serious fire hazard and pose a risk to the safety of the job site and anyone nearby. Therefore, it is important to properly dispose of or store rags away from any potential ignition sources to prevent accidents.

    Rate this question:

  • 11. 

    Minimum exit door width? in meter

    Correct Answer
    .71 m
    0.71
    0.71 meters
    0.71 meter
    71 cm
    71 centimeter
    Explanation
    The minimum exit door width is given in multiple units of measurement: .71 m, 0.71, 0.71 meters, 0.71 meter, 71 cm, and 71 centimeter. All of these options represent the same measurement of width, which is 0.71 meters or 71 centimeters.

    Rate this question:

  • 12. 

    Minimum floor to ceiling height? in meter

    Correct Answer
    2.30
    2.30 m
    2.30 meter
    Explanation
    The minimum floor to ceiling height is 2.30 meters. This means that the distance between the floor and the ceiling should be at least 2.30 meters.

    Rate this question:

  • 13. 

    Maximum height between landings for class A stair? in meters

    Correct Answer
    2.75
    2.75 m
    2.75 meters
    Explanation
    The maximum height between landings for a class A stair is 2.75 meters.

    Rate this question:

  • 14. 

    Minimum headroom for class A & B stairs?

    Correct Answer
    2.00
    2.0
    2
    Explanation
    The minimum headroom for class A & B stairs is 2.00, 2.0, or 2. This means that the vertical distance between the tread above and any obstruction above it must be at least 2.00, 2.0, or 2 units of measurement. This ensures that there is enough space for a person to comfortably walk up or down the stairs without hitting their head on any overhead obstructions.

    Rate this question:

  • 15. 

    Number of exits for place of assembly for 1000 occupants?

    Correct Answer
    4
    four
    Explanation
    The number of exits required for a place of assembly with 1000 occupants is four. This is because the building codes and regulations typically require a certain number of exits based on the occupancy load. For a place of assembly with 1000 occupants, it is necessary to have enough exits to ensure a safe and efficient evacuation in case of an emergency. Having four exits allows for multiple escape routes and helps to prevent overcrowding and potential bottlenecks during an evacuation.

    Rate this question:

  • 16. 

    Travel distance to an exit without fire sprinkler system?  in meters

    Correct Answer
    46.00 mts.
    46
    46 m
    46 meters
    46 meter
    46m
    46meters
    Explanation
    The correct answer is 46.00 mts. This answer indicates that the travel distance to an exit without a fire sprinkler system is 46.00 meters.

    Rate this question:

  • 17. 

    Travel distance to an exit with fire sprinkler system?   in meters    

    Correct Answer
    61.00 mts.
    61.00 m
    61
    61 meters
    61 m
    Explanation
    The travel distance to an exit with a fire sprinkler system is 61.00 meters.

    Rate this question:

  • 18. 

    Minimum spacing of rows of seats from back to back for a public assembly building? in cm

    Correct Answer
    0.83 mtr
    83 cm
    .83
    0.83 m
    0.83 meters
    83 centimeters
    83 centimeter
    Explanation
    The minimum spacing of rows of seats from back to back for a public assembly building is 83 centimeters or 0.83 meters. This measurement ensures that there is enough space for people to comfortably sit and move around in the building, while also adhering to safety regulations and building codes.

    Rate this question:

  • 19. 

    Maximum number of seats in a row in between aisles?

    Correct Answer
    14
    14 rows
    Explanation
    The maximum number of seats in a row in between aisles is 14. This means that there are 14 seats in each row, with aisles separating them. Additionally, there are a total of 14 rows.

    Rate this question:

  • 20. 

    A maximum number of seats in a row opening on to an aisle at one side?

    Correct Answer
    7
    7 seats
    Explanation
    The maximum number of seats in a row opening onto an aisle at one side is 7. This means that there are 7 seats in a row, with an aisle on one side. The question is asking for the maximum number of seats in this specific configuration, and the answer is 7.

    Rate this question:

  • 21. 

    Standard width of a seat without dividing arms for places of assembly?   in meters

    Correct Answer
    60 cms.
    60 cm
    60
    0.60
    .60
    .60 m
    .60 meters
    Explanation
    The standard width of a seat without dividing arms for places of assembly is 60 cm or 0.60 meters.

    Rate this question:

  • 22. 

    Minimum width of an aisle serving an occupant of 60?   in cm

    Correct Answer
    91
    91 cm
    91 centimeters
    91 centimeter
    Explanation
    The minimum width of an aisle serving an occupant of 60 is 91 cm. This provides enough space for the occupant to comfortably move through the aisle without feeling cramped or restricted.

    Rate this question:

  • 23. 

    Minimum headroom created by any projection from the ceiling?in meters

    Correct Answer
    2.00 mts
    2.00 m
    2.0 m
    2.0 meters
    2
    2 m
    2.0 meters
    2 meters
    Explanation
    The minimum headroom created by any projection from the ceiling is 2.00 meters.

    Rate this question:

  • 24. 

    Minimum clear width of turnstiles?

    Correct Answer
    56 cms.
    56 cm
    .56 m
    0.56 m
    .56 meters
    560 mm
    560 millimeter
    Explanation
    The minimum clear width of turnstiles is 56 cms, 56 cm, .56 m, 0.56 m, .56 meters, 560 mm, or 560 millimeters.

    Rate this question:

  • 25. 

    Minimum dimension of landings in the direction of travel for class A & B stairs? in cm

    Correct Answer
    112 cm
    112 centimeter
    112
    112 centimeters
    Explanation
    The minimum dimension of landings in the direction of travel for class A & B stairs is 112 cm. This measurement ensures that there is enough space for people to comfortably navigate the stairs and provides a safe area for them to rest if needed.

    Rate this question:

  • 26. 

    Minimum number of risers in any one (1) flight of stairs?           

    Correct Answer
    3
    three
    Explanation
    The minimum number of risers in any one flight of stairs is 3. This means that there must be at least 3 steps in a flight of stairs for it to be considered a proper staircase. The word "three" is provided as an alternative way of expressing the number 3.

    Rate this question:

  • 27. 

    Minimum height of a handrail above the upper surface of the tread?  in cm

    Correct Answer
    76 cm
    76 centimeters
    76
    76 centimeter
    Explanation
    The minimum height of a handrail above the upper surface of the tread is 76 cm. This measurement ensures that the handrail is at a suitable height for individuals to hold onto while using the stairs, providing stability and support.

    Rate this question:

  • 28. 

    Minimum clearance of a handrail from any wall?   in mm  

    Correct Answer
    38 mm
    Explanation
    The minimum clearance of a handrail from any wall is 38 mm. This means that there should be at least 38 mm of space between the handrail and the nearest wall. This clearance is necessary to ensure that there is enough room for a person's hand to comfortably grip the handrail without being obstructed by the wall. It also allows for easy movement along the handrail without any interference from the wall.

    Rate this question:

  • 29. 

    Minimum height of a guard rail? in cm

    Correct Answer
    91 cm
    91
    91 centimeters
    91 centimeter
    Explanation
    The minimum height of a guard rail is 91 cm. This measurement ensures that the guard rail is at a sufficient height to provide safety and prevent falls or accidents. It is important for guard rails to meet certain height requirements to effectively protect individuals and meet safety standards.

    Rate this question:

  • 30. 

    Maximum height of a guard rail? in cm

    Correct Answer
    106 cm
    106
    106 centimeters
    106 centimeter
    Explanation
    The maximum height of a guard rail is 106 cm.

    Rate this question:

  • 31. 

    Minimum inner radius of a monumental stair? in meters

    Correct Answer
    7.5
    7.50
    7.50 m
    750 centimeters
    750 centimeter
    7.50 meters
    7.5 meter
    7.5 m
    7.50 m
    Explanation
    The minimum inner radius of a monumental stair is 7.5 meters.

    Rate this question:

  • 32. 

    Minimum width of any balcony or bridge? in cm

    Correct Answer
    112 cm
    112
    112 centimeters
    1.12 m
    Explanation
    The minimum width of any balcony or bridge is 112 cm, which is equivalent to 112 centimeters or 1.12 m.

    Rate this question:

  • 33. 

    Minimum width of a class A ramp? in cm

    Correct Answer
    112 cm
    112
    112 centimeters
    Explanation
    The minimum width of a class A ramp is 112 cm.

    Rate this question:

  • 34. 

    Maximum rise of any floor from the balcony floor to which an access door leads? in cm

    Correct Answer
    20.3
    20.3 cm
    20.3 centimeter
    Explanation
    The maximum rise of any floor from the balcony floor to which an access door leads is 20.3 cm. This means that the height difference between the balcony floor and the highest point of any floor that can be accessed through the door is 20.3 cm.

    Rate this question:

  • 35. 

    Maximum vertical height in floors for an escalator?

    Correct Answer
    1 floor
    1
    1 flr
    1 fl
    Explanation
    The maximum vertical height for an escalator is typically measured in terms of floors. In this case, the correct answer options all represent the same measurement of 1 floor. This means that the escalator can transport individuals from one floor to another, with a maximum height equivalent to a single floor.

    Rate this question:

  • 36. 

    Minimum width of a fire escape stair for existing stairs? in cm

    Correct Answer
    55.9
    559 mm
    .559 m
    55.9 cm
    55.9 centimeter
    Explanation
    The minimum width of a fire escape stair for existing stairs is 55.9 cm. This is the standard measurement required to ensure that there is enough space for people to safely evacuate in case of an emergency.

    Rate this question:

  • 37. 

    Minimum width of landing for a fire escape stair for existing stairs? in cm  

    Correct Answer
    55.9 cm
    55.9 centimeters
    55.9 centimeter
    Explanation
    The minimum width of landing for a fire escape stair for existing stairs is 55.9 cm, 55.9 centimeters, or 55.9 centimeter.

    Rate this question:

  • 38. 

    Minimum tread for a fire escape stair for small buildings? in cm

    Correct Answer
    15.25 cm
    15.25 centimeter
    15.25 centimeters
    Explanation
    The minimum tread for a fire escape stair for small buildings is 15.25 cm or 15.25 centimeters.

    Rate this question:

  • 39. 

    Maximum rise of fire escape stair for a small building?    in cm     

    Correct Answer
    30.5 cm
    30.5 centimeter
    30.5 centimeters
    Explanation
    The maximum rise of a fire escape stair for a small building is 30.5 cm, which is equivalent to 30.5 centimeters. This measurement is important to ensure that the stairs are safe and easily navigable in case of an emergency. It is crucial to adhere to building codes and regulations to provide a means of escape for occupants in the event of a fire or other hazardous situations.

    Rate this question:

  • 40. 

    Maximum rise of fire escape stair for existing stairs? in cm            

    Correct Answer
    22.9 cm
    22.9 centimeter
    22.9 centimeters
    Explanation
    The maximum rise of a fire escape stair for existing stairs is 22.9 cm. This means that the vertical distance between each step cannot exceed 22.9 cm. This is important for the safety and ease of use of the stairs, as a higher rise could be difficult to climb and potentially dangerous in emergency situations.

    Rate this question:

  • 41. 

    Maximum height between landings for a fire escape stair for existing stairs? in meters

    Correct Answer
    3.66 m
    3.66 meters
    3.66 meter
    3.66
    Explanation
    The maximum height between landings for a fire escape stair for existing stairs is 3.66 meters.

    Rate this question:

  • 42. 

    Minimum headroom clearance for a fire escape stair for existing stairs? in meters  

    Correct Answer
    2.13 m
    2.13 meter
    2.13 meters
    2.13
    Explanation
    The minimum headroom clearance for a fire escape stair for existing stairs is 2.13 meters. This ensures that there is enough space for individuals to safely pass through the stairwell without hitting their heads on any obstructions.

    Rate this question:

  • 43. 

    Minimum headroom clearance for a fire escape stair for small buildings? in meters      

    Correct Answer
    1.98
    1.98 m
    1.98 meters
    1.98 meter
    Explanation
    The minimum headroom clearance for a fire escape stair for small buildings is 1.98 meters. This means that there should be a minimum vertical distance of 1.98 meters between the floor and any obstructions or structures above the fire escape stair. This clearance is necessary to ensure that people can safely and comfortably use the fire escape stair without hitting their heads on any overhead obstacles.

    Rate this question:

  • 44. 

    Number of exits for place of assembly for 600-1000 occupants?           

    Correct Answer
    3
    three
    Explanation
    The number of exits required for a place of assembly with 600-1000 occupants is three. This is based on safety regulations and building codes that mandate a sufficient number of exits to ensure the safe evacuation of occupants in case of an emergency. Having multiple exits helps to prevent overcrowding and allows for a faster and more efficient evacuation process.

    Rate this question:

  • 45. 

    Maximum occupant load for a class C public assembly.            

    Correct Answer
    Maximum occupant load for a class C public assembly. 50-300
    50 to 300
    50 - 300
    Explanation
    The correct answer is "50-300, 50 to 300, 50 - 300". This answer indicates that the maximum occupant load for a class C public assembly can range from 50 to 300 people. It is important to note that the exact number within this range may vary depending on specific regulations and guidelines.

    Rate this question:

  • 46. 

    Minimum number of exit for an Institutional type of structure?

    Correct Answer
    2
    two
    Explanation
    The minimum number of exits required for an institutional type of structure is two. This is necessary to ensure the safety and efficient evacuation of occupants in case of emergencies such as fires or other hazards. Having multiple exits allows for multiple escape routes and reduces the risk of congestion or blockage during an evacuation. It also ensures that occupants have alternative paths to exit the building, increasing their chances of reaching safety quickly.

    Rate this question:

  • 47. 

    Maximum travel distance between room door intended as exit access and exit with sprinkler system for institutional use? in meters

    Correct Answer
    30
    30 m
    30 meter
    30 meters
    Explanation
    The maximum travel distance between a room door intended as an exit access and an exit with a sprinkler system for institutional use is 30 meters.

    Rate this question:

  • 48. 

    Maximum travel distance from the door of any room to exit for hotels with sprinkler? in meters

    Correct Answer
    30
    30 m
    30 meter
    30 meters
    Explanation
    The maximum travel distance from the door of any room to the exit for hotels with sprinklers is 30 meters.

    Rate this question:

  • 49. 

    Maximum travel distance from the main entrance door to exit for apartments with sprinkler? in meters

    Correct Answer
    31
    31 m
    31 meter
    31 meters
    Explanation
    The maximum travel distance from the main entrance door to the exit for apartments with sprinklers is 31 meters.

    Rate this question:

  • 50. 

    Minimum increase in width for an aisle per linear meter? in cm          

    Correct Answer
    2.5
    2.5 cm
    2.5 centimeter
    2.5 centimeters
    Explanation
    The minimum increase in width for an aisle per linear meter is 2.5 cm, 2.5 centimeter, or 2.5 centimeters.

    Rate this question:

Quiz Review Timeline +

Our quizzes are rigorously reviewed, monitored and continuously updated by our expert board to maintain accuracy, relevance, and timeliness.

  • Current Version
  • Mar 17, 2023
    Quiz Edited by
    ProProfs Editorial Team
  • Nov 26, 2012
    Quiz Created by
    Kubo
Back to Top Back to top
Advertisement
×

Wait!
Here's an interesting quiz for you.

We have other quizzes matching your interest.