1.
What is installed in the ducts and mechanical passageways to prevent the fire from spreading?
Correct Answer
B. Fire dampers
Explanation
Fire dampers are installed in ducts and mechanical passageways to prevent the spread of fire. These dampers are designed to automatically close when they detect heat or smoke, effectively blocking the passage of fire and smoke. This helps to contain the fire and prevent it from spreading to other areas of a building. Fire dampers are an important safety feature in buildings, as they help to protect occupants and minimize property damage in the event of a fire.
2.
Why escalators have a built-in fire alarm system?
Correct Answer
C. It's the hole for each floors
Explanation
The correct answer is that escalators have a built-in fire alarm system because it is the best location for the alarm system as it is located in common areas.
3.
When water comes out as soon s the fire sprinkler system is activated, this system is called?
Correct Answer
A. Wet pipe
Explanation
When water comes out as soon as the fire sprinkler system is activated, it indicates that the system is already filled with water. This type of system, known as a wet pipe system, is the most common and simplest type of sprinkler system. It is designed for areas where the temperature is above freezing, as the water in the pipes is constantly pressurized and ready to be discharged immediately upon activation. This ensures a rapid response to a fire and helps to suppress it effectively. The other options, such as dry pipe, pre-action, and deluge fire systems, have different mechanisms and are used in specific situations.
4.
A fire proof door with metal covering?
Correct Answer
A. Kalamein
Explanation
Kalamein is the correct answer because it refers to a type of fireproof door with a metal covering. This type of door is designed to withstand high temperatures and prevent the spread of fire. It is commonly used in commercial buildings and other areas where fire safety is a priority. The metal covering provides additional protection and durability, making it an effective choice for fire doors.
5.
Smoke prevention is :
more important than fire prevention
as important as fire prevention x
less important than fire prevention,
because fire is more critical than smoke
it doesn't matter, it's just smoke.
Correct Answer
B.
as important as fire prevention
Explanation
The correct answer is "as important as fire prevention" because smoke prevention is just as crucial as fire prevention. Smoke is often an early indicator of a fire and can be just as dangerous, if not more, due to the inhalation of toxic fumes. Therefore, both fire prevention and smoke prevention should be given equal importance in order to ensure the safety of individuals and minimize potential damage.
6.
Why Cable wires and grounding wires are shielded?
Correct Answer
C. Fire proofing
Explanation
Cable wires and grounding wires are shielded for fireproofing purposes. Shielding helps prevent the spread of fire by containing any potential sparks or flames within the wires, reducing the risk of fire hazards. It acts as a protective barrier, minimizing the chances of fire accidents caused by electrical faults or short circuits. Shielding provides an additional layer of safety, ensuring that the wires can withstand high temperatures and prevent fires from spreading in case of emergencies.
7.
Safest material for exits?
Correct Answer
B. Steel
Explanation
Steel is the safest material for exits because it has high strength and durability, making it resistant to fire, impact, and other hazards. It can withstand extreme temperatures and provide structural stability during emergencies, ensuring the safety of people exiting a building. Reinforced concrete and mortar may also offer some level of safety, but steel is specifically designed and widely recognized for its superior performance in exit applications. Therefore, steel is considered the safest material for exits.
8.
Material best used for stairs in a fire restrictive zone?
Correct Answer
B. Reinforced concrete
Explanation
Reinforced concrete is the best material for stairs in a fire restrictive zone because it has excellent fire resistance properties. Concrete is a non-combustible material and does not contribute to the spread of fire. Additionally, the presence of steel reinforcement provides added strength and durability to the structure. This combination of concrete and steel makes reinforced concrete a reliable choice for stairs in areas where fire safety is a priority.
9.
Which material is the least fire resistant?
Correct Answer
B. Wood
Explanation
Wood is the least fire resistant material among the options given. Wood is a combustible material that easily catches fire and burns rapidly. It has a low ignition point and releases flammable gases when heated, which further fuels the fire. In comparison, gypsum, CHB (concrete hollow blocks), and steel have higher fire resistance properties. Gypsum is a non-combustible material that acts as a fire barrier, while CHB and steel are less prone to burning and can withstand high temperatures for a longer time before succumbing to fire.
10.
Why should rags not be left beside the can of paints at job sites especially during night time when it is most likely to be unattended?
Correct Answer
C. It might ignite fire
Explanation
Leaving rags beside a can of paints at job sites, especially during nighttime when it is unattended, can be dangerous because they might ignite a fire. Rags can become flammable when they come into contact with certain chemicals or substances found in paints. If the rags are left in a pile or in a confined space, they can generate heat and potentially catch fire. This can lead to a serious fire hazard and pose a risk to the safety of the job site and anyone nearby. Therefore, it is important to properly dispose of or store rags away from any potential ignition sources to prevent accidents.
11.
Minimum exit door width? in meter
Correct Answer
.71 m
0.71
0.71 meters
0.71 meter
71 cm
71 centimeter
Explanation
The minimum exit door width is given in multiple units of measurement: .71 m, 0.71, 0.71 meters, 0.71 meter, 71 cm, and 71 centimeter. All of these options represent the same measurement of width, which is 0.71 meters or 71 centimeters.
12.
Minimum floor to ceiling height? in meter
Correct Answer
2.30
2.30 m
2.30 meter
Explanation
The minimum floor to ceiling height is 2.30 meters. This means that the distance between the floor and the ceiling should be at least 2.30 meters.
13.
Maximum height between landings for class A stair? in meters
Correct Answer
2.75
2.75 m
2.75 meters
Explanation
The maximum height between landings for a class A stair is 2.75 meters.
14.
Minimum headroom for class A & B stairs?
Correct Answer
2.00
2.0
2
Explanation
The minimum headroom for class A & B stairs is 2.00, 2.0, or 2. This means that the vertical distance between the tread above and any obstruction above it must be at least 2.00, 2.0, or 2 units of measurement. This ensures that there is enough space for a person to comfortably walk up or down the stairs without hitting their head on any overhead obstructions.
15.
Number of exits for place of assembly for 1000 occupants?
Correct Answer
4
four
Explanation
The number of exits required for a place of assembly with 1000 occupants is four. This is because the building codes and regulations typically require a certain number of exits based on the occupancy load. For a place of assembly with 1000 occupants, it is necessary to have enough exits to ensure a safe and efficient evacuation in case of an emergency. Having four exits allows for multiple escape routes and helps to prevent overcrowding and potential bottlenecks during an evacuation.
16.
Travel distance to an exit without fire sprinkler system? in meters
Correct Answer
46.00 mts.
46
46 m
46 meters
46 meter
46m
46meters
Explanation
The correct answer is 46.00 mts. This answer indicates that the travel distance to an exit without a fire sprinkler system is 46.00 meters.
17.
Travel distance to an exit with fire sprinkler system? in meters
Correct Answer
61.00 mts.
61.00 m
61
61 meters
61 m
Explanation
The travel distance to an exit with a fire sprinkler system is 61.00 meters.
18.
Minimum spacing of rows of seats from back to back for a public assembly building? in cm
Correct Answer
0.83 mtr
83 cm
.83
0.83 m
0.83 meters
83 centimeters
83 centimeter
Explanation
The minimum spacing of rows of seats from back to back for a public assembly building is 83 centimeters or 0.83 meters. This measurement ensures that there is enough space for people to comfortably sit and move around in the building, while also adhering to safety regulations and building codes.
19.
Maximum number of seats in a row in between aisles?
Correct Answer
14
14 rows
Explanation
The maximum number of seats in a row in between aisles is 14. This means that there are 14 seats in each row, with aisles separating them. Additionally, there are a total of 14 rows.
20.
A maximum number of seats in a row opening on to an aisle at one side?
Correct Answer
7
7 seats
Explanation
The maximum number of seats in a row opening onto an aisle at one side is 7. This means that there are 7 seats in a row, with an aisle on one side. The question is asking for the maximum number of seats in this specific configuration, and the answer is 7.
21.
Standard width of a seat without dividing arms for places of assembly? in meters
Correct Answer
60 cms.
60 cm
60
0.60
.60
.60 m
.60 meters
Explanation
The standard width of a seat without dividing arms for places of assembly is 60 cm or 0.60 meters.
22.
Minimum width of an aisle serving an occupant of 60? in cm
Correct Answer
91
91 cm
91 centimeters
91 centimeter
Explanation
The minimum width of an aisle serving an occupant of 60 is 91 cm. This provides enough space for the occupant to comfortably move through the aisle without feeling cramped or restricted.
23.
Minimum headroom created by any projection from the ceiling?in meters
Correct Answer
2.00 mts
2.00 m
2.0 m
2.0 meters
2
2 m
2.0 meters
2 meters
Explanation
The minimum headroom created by any projection from the ceiling is 2.00 meters.
24.
Minimum clear width of turnstiles?
Correct Answer
56 cms.
56 cm
.56 m
0.56 m
.56 meters
560 mm
560 millimeter
Explanation
The minimum clear width of turnstiles is 56 cms, 56 cm, .56 m, 0.56 m, .56 meters, 560 mm, or 560 millimeters.
25.
Minimum dimension of landings in the direction of travel for class A & B stairs? in cm
Correct Answer
112 cm
112 centimeter
112
112 centimeters
Explanation
The minimum dimension of landings in the direction of travel for class A & B stairs is 112 cm. This measurement ensures that there is enough space for people to comfortably navigate the stairs and provides a safe area for them to rest if needed.
26.
Minimum number of risers in any one (1) flight of stairs?
Correct Answer
3
three
Explanation
The minimum number of risers in any one flight of stairs is 3. This means that there must be at least 3 steps in a flight of stairs for it to be considered a proper staircase. The word "three" is provided as an alternative way of expressing the number 3.
27.
Minimum height of a handrail above the upper surface of the tread? in cm
Correct Answer
76 cm
76 centimeters
76
76 centimeter
Explanation
The minimum height of a handrail above the upper surface of the tread is 76 cm. This measurement ensures that the handrail is at a suitable height for individuals to hold onto while using the stairs, providing stability and support.
28.
Minimum clearance of a handrail from any wall? in mm
Correct Answer
38 mm
Explanation
The minimum clearance of a handrail from any wall is 38 mm. This means that there should be at least 38 mm of space between the handrail and the nearest wall. This clearance is necessary to ensure that there is enough room for a person's hand to comfortably grip the handrail without being obstructed by the wall. It also allows for easy movement along the handrail without any interference from the wall.
29.
Minimum height of a guard rail? in cm
Correct Answer
91 cm
91
91 centimeters
91 centimeter
Explanation
The minimum height of a guard rail is 91 cm. This measurement ensures that the guard rail is at a sufficient height to provide safety and prevent falls or accidents. It is important for guard rails to meet certain height requirements to effectively protect individuals and meet safety standards.
30.
Maximum height of a guard rail? in cm
Correct Answer
106 cm
106
106 centimeters
106 centimeter
Explanation
The maximum height of a guard rail is 106 cm.
31.
Minimum inner radius of a monumental stair? in meters
Correct Answer
7.5
7.50
7.50 m
750 centimeters
750 centimeter
7.50 meters
7.5 meter
7.5 m
7.50 m
Explanation
The minimum inner radius of a monumental stair is 7.5 meters.
32.
Minimum width of any balcony or bridge? in cm
Correct Answer
112 cm
112
112 centimeters
1.12 m
Explanation
The minimum width of any balcony or bridge is 112 cm, which is equivalent to 112 centimeters or 1.12 m.
33.
Minimum width of a class A ramp? in cm
Correct Answer
112 cm
112
112 centimeters
Explanation
The minimum width of a class A ramp is 112 cm.
34.
Maximum rise of any floor from the balcony floor to which an access door leads? in cm
Correct Answer
20.3
20.3 cm
20.3 centimeter
Explanation
The maximum rise of any floor from the balcony floor to which an access door leads is 20.3 cm. This means that the height difference between the balcony floor and the highest point of any floor that can be accessed through the door is 20.3 cm.
35.
Maximum vertical height in floors for an escalator?
Correct Answer
1 floor
1
1 flr
1 fl
Explanation
The maximum vertical height for an escalator is typically measured in terms of floors. In this case, the correct answer options all represent the same measurement of 1 floor. This means that the escalator can transport individuals from one floor to another, with a maximum height equivalent to a single floor.
36.
Minimum width of a fire escape stair for existing stairs? in cm
Correct Answer
55.9
559 mm
.559 m
55.9 cm
55.9 centimeter
Explanation
The minimum width of a fire escape stair for existing stairs is 55.9 cm. This is the standard measurement required to ensure that there is enough space for people to safely evacuate in case of an emergency.
37.
Minimum width of landing for a fire escape stair for existing stairs? in cm
Correct Answer
55.9 cm
55.9 centimeters
55.9 centimeter
Explanation
The minimum width of landing for a fire escape stair for existing stairs is 55.9 cm, 55.9 centimeters, or 55.9 centimeter.
38.
Minimum tread for a fire escape stair for small buildings? in cm
Correct Answer
15.25 cm
15.25 centimeter
15.25 centimeters
Explanation
The minimum tread for a fire escape stair for small buildings is 15.25 cm or 15.25 centimeters.
39.
Maximum rise of fire escape stair for a small building? in cm
Correct Answer
30.5 cm
30.5 centimeter
30.5 centimeters
Explanation
The maximum rise of a fire escape stair for a small building is 30.5 cm, which is equivalent to 30.5 centimeters. This measurement is important to ensure that the stairs are safe and easily navigable in case of an emergency. It is crucial to adhere to building codes and regulations to provide a means of escape for occupants in the event of a fire or other hazardous situations.
40.
Maximum rise of fire escape stair for existing stairs? in cm
Correct Answer
22.9 cm
22.9 centimeter
22.9 centimeters
Explanation
The maximum rise of a fire escape stair for existing stairs is 22.9 cm. This means that the vertical distance between each step cannot exceed 22.9 cm. This is important for the safety and ease of use of the stairs, as a higher rise could be difficult to climb and potentially dangerous in emergency situations.
41.
Maximum height between landings for a fire escape stair for existing stairs? in meters
Correct Answer
3.66 m
3.66 meters
3.66 meter
3.66
Explanation
The maximum height between landings for a fire escape stair for existing stairs is 3.66 meters.
42.
Minimum headroom clearance for a fire escape stair for existing stairs? in meters
Correct Answer
2.13 m
2.13 meter
2.13 meters
2.13
Explanation
The minimum headroom clearance for a fire escape stair for existing stairs is 2.13 meters. This ensures that there is enough space for individuals to safely pass through the stairwell without hitting their heads on any obstructions.
43.
Minimum headroom clearance for a fire escape stair for small buildings? in meters
Correct Answer
1.98
1.98 m
1.98 meters
1.98 meter
Explanation
The minimum headroom clearance for a fire escape stair for small buildings is 1.98 meters. This means that there should be a minimum vertical distance of 1.98 meters between the floor and any obstructions or structures above the fire escape stair. This clearance is necessary to ensure that people can safely and comfortably use the fire escape stair without hitting their heads on any overhead obstacles.
44.
Number of exits for place of assembly for 600-1000 occupants?
Correct Answer
3
three
Explanation
The number of exits required for a place of assembly with 600-1000 occupants is three. This is based on safety regulations and building codes that mandate a sufficient number of exits to ensure the safe evacuation of occupants in case of an emergency. Having multiple exits helps to prevent overcrowding and allows for a faster and more efficient evacuation process.
45.
Maximum occupant load for a class C public assembly.
Correct Answer
Maximum occupant load for a class C public assembly.
50-300
50 to 300
50 - 300
Explanation
The correct answer is "50-300, 50 to 300, 50 - 300". This answer indicates that the maximum occupant load for a class C public assembly can range from 50 to 300 people. It is important to note that the exact number within this range may vary depending on specific regulations and guidelines.
46.
Minimum number of exit for an Institutional type of structure?
Correct Answer
2
two
Explanation
The minimum number of exits required for an institutional type of structure is two. This is necessary to ensure the safety and efficient evacuation of occupants in case of emergencies such as fires or other hazards. Having multiple exits allows for multiple escape routes and reduces the risk of congestion or blockage during an evacuation. It also ensures that occupants have alternative paths to exit the building, increasing their chances of reaching safety quickly.
47.
Maximum travel distance between room door intended as exit access and exit with sprinkler system for institutional use? in meters
Correct Answer
30
30 m
30 meter
30 meters
Explanation
The maximum travel distance between a room door intended as an exit access and an exit with a sprinkler system for institutional use is 30 meters.
48.
Maximum travel distance from the door of any room to exit for hotels with sprinkler? in meters
Correct Answer
30
30 m
30 meter
30 meters
Explanation
The maximum travel distance from the door of any room to the exit for hotels with sprinklers is 30 meters.
49.
Maximum travel distance from the main entrance door to exit for apartments with sprinkler? in meters
Correct Answer
31
31 m
31 meter
31 meters
Explanation
The maximum travel distance from the main entrance door to the exit for apartments with sprinklers is 31 meters.
50.
Minimum increase in width for an aisle per linear meter? in cm
Correct Answer
2.5
2.5 cm
2.5 centimeter
2.5 centimeters
Explanation
The minimum increase in width for an aisle per linear meter is 2.5 cm, 2.5 centimeter, or 2.5 centimeters.