1.
Which of these statements is true?
Correct Answer
D. All of them
Explanation
All of the statements are true. The first statement explains that the dysfunction or hypofunction of lacrimal glands and the consequent reduced volume of the aqueous layer of the tear film are the underlying causes of ADDE (aqueous-deficient dry eye). The second statement states that dysfunction or hypofunction of Meibomian glands or reduced production of mucin proteins by conjunctival goblet cells lead to increased tear fluid evaporation and result in EDED (evaporative dry eye). The third statement explains that in more severe cases of Dry Eye, both lacrimal and Meibomian glands may be impaired, leading to a mixed phenotype characterized by signs of both ADDE and EDE. Therefore, all the statements are true.
2.
The objective of the TBUT / NIBUT is to evaluate:
Correct Answer
A. The tear film stability
Explanation
The TBUT/NIBUT test is used to evaluate the tear film stability. This test measures the time it takes for the tear film to break up or evaporate. By assessing tear film stability, eye care professionals can determine if there are any issues with tear production or tear film composition. This test helps in diagnosing conditions such as dry eye syndrome or meibomian gland dysfunction. Therefore, the correct answer is "The tear film stability."
3.
The specific tests for the evaluation of the Meibomian glands are:
Correct Answer
C. All of the above
Explanation
The correct answer is "All of the above." This means that all of the tests mentioned in the options (OSDI, SPEED, Schirmer, fluorescein staining, measurement of lower tear meniscus height with an OCT, osmolarity, TBUT, phenol read thread, and rose Bengal staining) are specific tests used for the evaluation of the Meibomian glands. These tests assess various aspects of the Meibomian glands' function, tear production, tear quality, and ocular surface health.
4.
The non-contact meibography allows the observation of MG structure in silhouette through illumination of the eyelids from the skin side and is thereby able to detect morphological abnormalities.
Correct Answer
A. True
Explanation
The non-contact meibography technique enables the visualization of the structure of the meibomian glands (MG) by illuminating the eyelids from the skin side. This method allows for the detection of any abnormalities in the morphology of the MG. Therefore, the statement is true as it accurately describes the capabilities of non-contact meibography.
5.
- The LipiView : accurately measures lipid layer thickness; 2) evaluates blink rate; 3) visualizes Meibomian gland structure; 4) Allows visualization of Demodex; 5) can detect MGD in its earliest stages.
Correct Answer
A. 1, 2, 3
Explanation
The LipiView is a device that has multiple functions. It accurately measures the thickness of the lipid layer, evaluates blink rate, and visualizes the structure of the Meibomian glands. Therefore, options 1, 2, and 3 are correct because they include these three functions. Option 4 is incorrect because it does not include the visualization of Meibomian gland structure. Option 5 is also incorrect because it does not include the accurate measurement of the lipid layer thickness.
6.
The LipiScan accurately measures lipid layer thickness, evaluates blink rate and visualizes Meibomian gland structure.
Correct Answer
B. False
Explanation
The statement is false because the LipiScan does not evaluate blink rate. It accurately measures lipid layer thickness and visualizes Meibomian gland structure, but it does not have the capability to evaluate blink rate.
7.
The LipiFlow:
Correct Answer
C. All of the above.
Explanation
The LipiFlow is composed of two primary components, an ocular disposable component (Activator) and a Handheld Control System. It also provides a heated surface with a nominal average temperature at the palpebral conjunctiva between 41°C and 43°C. Therefore, the correct answer is "All of the above."
8.
From a business standpoint, who would be potentially interested in our Dry Eye technology?
Correct Answer
A. General opHthalmologist / Comprehensive opHthalmologist
Explanation
General ophthalmologists and comprehensive ophthalmologists would be potentially interested in our Dry Eye technology. This is because they are primary eye care providers who diagnose and treat a wide range of eye conditions, including dry eye. They are likely to encounter patients with dry eye symptoms and would benefit from having access to advanced technology for diagnosis and treatment. Other specialists like cataract and refractive surgeons, glaucoma specialists, and oculoplastic surgeons may also have an interest in our technology, but the primary target audience would be general and comprehensive ophthalmologists.
9.
The SBM Idra accurately measures lipid layer thickness, evaluates blink rate, visualizes MG structure, allows visualization of Demodex, and mesures the tear meniscus height.
Correct Answer
A. True
Explanation
The statement is true because the SBM Idra is a device that is specifically designed to accurately measure lipid layer thickness, evaluate blink rate, visualize MG (meibomian gland) structure, allow visualization of Demodex (a type of mite that can infest eyelashes), and measure tear meniscus height. This device combines multiple functions to provide comprehensive information about the tear film and ocular surface, making it a valuable tool in assessing and managing various ocular conditions.
10.
The Oculus Keratograph 5 M:
Correct Answer
D. All of the above.
Explanation
The Oculus Keratograph 5 M is a standard topographer that has been on the market for a few years. It is not only focused on dry eye analysis but also performs various examinations for dry eye disease (DED) such as meibography, non-invasive tear breakup time (NIBUT), tear meniscus evaluation, and redness detection. Therefore, the correct answer is "All of the above."
11.
ESW Vision TearCheck allows the evaluation of the staining of the cornea and the conjunctiva, of the stability of the tear film and of the anatomy of the meibomian glands.
Correct Answer
A. True
Explanation
ESW Vision TearCheck is a tool that enables the assessment of various aspects related to the eyes, such as the staining of the cornea and conjunctiva, the stability of the tear film, and the anatomy of the meibomian glands. This indicates that the statement is accurate and the answer is true.
12.
The Espansione ME-Check allows demodex screening.
Correct Answer
A. True
Explanation
The Espansione ME-Check is a screening tool specifically designed for demodex. It is used to detect the presence of demodex mites on the skin. Therefore, the statement that the Espansione ME-Check allows demodex screening is true.
13.
The following test can be performed with the Topcon CA-800: a) Meibography; b) Topography; c) Corneal aberrometry; d) Tear meniscus analysis; e) Fluoroscein analysis; f) Contact lenses fitting; g) Pupillometry; h) Demodex screening; i) White to White measurments;
Correct Answer
A. A,b,c,d,e,f,g,i
Explanation
The Topcon CA-800 can perform the following tests: Meibography, Topography, Corneal aberrometry, Tear meniscus analysis, Fluorescein analysis, Contact lenses fitting, Pupillometry, and White to White measurements.
14.
The MX2 Camera is an improved version of Meibox.
Correct Answer
A. True
Explanation
The given statement suggests that the MX2 Camera is an upgraded or enhanced version of the Meibox. This implies that the MX2 Camera is an improved model compared to the Meibox. Therefore, the statement is true.