1.
What device is used to measure line current of 200A and above?
Explanation
A clamp meter, also known as a clamp ammeter, is used to measure line current of 200A and above. This device is designed with a clamp-like mechanism that can be easily attached around a conductor, allowing it to measure the current flowing through the conductor without the need for direct contact. The clamp meter uses the principle of electromagnetic induction to accurately measure the current passing through the conductor. It is commonly used in electrical and electronic industries for troubleshooting, maintenance, and installation purposes.
2.
In measuring electrical energy or power ___ is use.
Explanation
A wattmeter is used in measuring electrical energy or power. A wattmeter is a device that measures the electric power in watts of any given circuit. It is commonly used in electrical engineering and is essential for monitoring and controlling power consumption. The wattmeter measures both the voltage and current in a circuit and calculates the power by multiplying the two values together. This measurement is crucial for various applications, such as energy management, load balancing, and efficiency optimization in electrical systems.
3.
What device is used to measure electrical resistance?
Correct Answer
B. CHMmeter
4.
What device is used to measure insulation resistance?
Correct Answer
C. Megger Tester
Explanation
A Megger Tester is a device specifically designed to measure insulation resistance. It is commonly used in electrical systems to check the integrity of insulation materials and determine if there are any faults or leakage. Unlike the other options listed, a Megger Tester is specifically designed for insulation resistance testing, making it the correct answer in this context.
5.
What device is used to measure power consumption?
Correct Answer
A. Kilowatt hour meter
Explanation
A kilowatt hour meter is used to measure power consumption. It calculates the amount of electrical energy consumed over a period of time by measuring the power (in kilowatts) and the duration (in hours). This device is commonly used in households and industries to monitor and control energy usage, as well as for billing purposes. It provides an accurate measurement of power consumption, allowing users to track their electricity usage and make informed decisions about energy conservation.
6.
Device used to measure current is?
Correct Answer
D. Ammeter
Explanation
An ammeter is a device used to measure the flow of electric current in a circuit. It is designed to be connected in series with the circuit, allowing the current to pass through it and provide an accurate measurement. The other options, such as a wattmeter, megger tester, and growler tester, are not specifically designed to measure current. A wattmeter measures power, a megger tester measures insulation resistance, and a growler tester is used to detect faults in electric motors. Therefore, an ammeter is the correct device to measure current.
7.
Device used to gauge for voltage/emf ____
Correct Answer
A. Voltmeter
Explanation
A voltmeter is a device used to measure voltage or electromotive force (emf). It is specifically designed to gauge the potential difference between two points in an electric circuit. By connecting the voltmeter across the points of interest, it can accurately display the voltage value. In contrast, a growler tester is used to detect faults in electrical machines, a clamp meter measures current, and a kilowatt hour meter measures electrical energy consumption. Therefore, the most appropriate device for gauging voltage/emf is a voltmeter.
8.
What device is used in testing armature of short circuit coils?
Correct Answer
B. Growler tester
Explanation
A growler tester is used in testing the armature of short circuit coils. A growler tester is a device that generates a magnetic field and is used to check for short circuits or open circuits in the armature windings of electrical machines. It works by inducing a magnetic field in the armature and detecting any changes in the magnetic field, which can indicate faults in the coil windings. Therefore, a growler tester is the correct device for testing the armature of short circuit coils.
9.
What tool is used in bending pvc pipe?
Correct Answer
heat gun
piping heater
Explanation
A heat gun or piping heater is used in bending PVC pipes. These tools provide heat to soften the PVC material, making it flexible and easier to bend into the desired shape. The heat gun or piping heater helps to prevent the PVC pipe from cracking or breaking during the bending process. By applying heat, the PVC pipe becomes pliable, allowing it to be bent without causing damage to the pipe.
10.
A device is used to change the value of volage.____
Correct Answer
Transformer
Explanation
A transformer is a device that is used to change the value of voltage. It is an electrical device that consists of two or more coils of wire wrapped around a core. It works on the principle of electromagnetic induction, where an alternating current in one coil induces a voltage in the other coil. This allows the voltage to be increased or decreased depending on the turns ratio of the coils. Transformers are commonly used in power distribution systems to step up or step down voltages for efficient transmission and utilization of electrical energy.
11.
Transformer is normally rated in ______
Correct Answer
KVA (kilo-volt-ampere)
Explanation
The transformer is normally rated in KVA (kilo-volt-ampere) because it is a measure of the apparent power of the transformer. KVA takes into account both the voltage and current, indicating the total power capacity of the transformer. It is important to rate transformers in KVA as it helps in determining the appropriate size and capacity of the transformer for a given application, ensuring efficient and safe operation.
12.
1 KVA is equal to _____
Correct Answer
1000 volts
Explanation
1 KVA is equal to 1000 volts because KVA stands for kilovolt-ampere, which is a unit of apparent power in an electrical circuit. It represents the total power in a circuit, including both the real power (measured in watts) and the reactive power (measured in volt-amperes reactive). Since 1 KVA is equal to 1000 volt-amperes, it can be equated to 1000 volts.
13.
KVAR means ______
Correct Answer
Kilo volt ampere rating
Explanation
KVAR is an acronym that stands for "kilo volt ampere rating." This term is used to measure the reactive power in an electrical system. Reactive power is the power that is required to maintain the electric and magnetic fields in an alternating current circuit. KVAR rating is important in power factor correction and determining the efficiency of electrical equipment. It helps in optimizing the power flow and reducing energy losses in electrical systems.
14.
What is used to gauge wire size _____
Correct Answer
wire gauge
Explanation
Wire gauge is used to measure the size of a wire. It is a measurement system that determines the diameter or cross-sectional area of a wire. By using a wire gauge, one can determine the appropriate wire size for a specific application, such as electrical wiring or jewelry making. The wire gauge provides a standardized scale that allows for easy comparison and selection of wires based on their size.
15.
A device that detect smoke in case of fire is _______
Correct Answer
smoke detector
Explanation
A smoke detector is a device that is designed to detect smoke in the event of a fire. It is equipped with sensors that can sense the presence of smoke particles in the air. When smoke is detected, the detector triggers an alarm to alert the occupants of the building and prompt them to take necessary actions to ensure their safety. Smoke detectors are commonly used in residential and commercial buildings as an essential safety measure to detect fires at an early stage and prevent potential disasters.
16.
What is used to remove rubber tape in a joint of wire?
Correct Answer
electricians knife
Explanation
An electrician's knife is used to remove rubber tape in a joint of wire. The knife has a sharp blade that can easily cut through the rubber tape, allowing for the removal of the tape without damaging the wire or the joint. This tool is commonly used by electricians to safely and effectively remove insulation or tape from wires during electrical work.
17.
A device used to remove sharp burns or rough edges is ____
Correct Answer
tappered reamer
Explanation
A tapered reamer is a tool that is used to remove sharp burns or rough edges. It has a tapered shape, meaning that it gradually widens towards one end. This allows it to fit into holes or openings of different sizes. By rotating the tapered reamer inside the hole, it smooths out the edges and removes any rough or sharp areas. This tool is commonly used in metalworking or woodworking to ensure a clean and smooth finish.
18.
What device that protects the motor from overload?
Correct Answer
overload relays
orverload protection
Explanation
The correct answer is overload relays. Overload relays are devices that protect the motor from overload by monitoring the current flowing through the motor. If the current exceeds a certain threshold, the overload relay will trip and disconnect the motor from the power source, preventing damage to the motor. Overload protection, on the other hand, is a broader term that encompasses various methods and devices used to protect motors from overload, including overload relays.
19.
What is the used of tappered reamer?
Correct Answer
to remove sharp burns or rough edges
Explanation
A tapered reamer is a tool used to gradually enlarge and shape holes in materials such as metal or wood. It is designed with a tapered end that allows for precision and control while removing sharp burrs or rough edges from the inside of a hole. By rotating the reamer in a clockwise motion, it smooths out the surface and creates a more even and polished finish, ensuring that the hole is clean and free from any imperfections.
20.
Fuse filler is used to removed?
Correct Answer
link
21.
When cutting a rigid conduit, electrician must used ___?
Correct Answer
3 wheel pipe cutter
Explanation
A 3 wheel pipe cutter is the correct tool for an electrician to use when cutting a rigid conduit. This type of cutter is specifically designed to cut through pipes and conduits with precision and ease. The three wheels provide stability and balance while cutting, ensuring a clean and accurate cut. Other types of cutters may not be suitable for cutting rigid conduits and may result in uneven or jagged cuts. Therefore, a 3 wheel pipe cutter is the recommended tool for this task.